AEC-Q200车规晶振可靠性测试说明(英文版)
RELIABILITY SPECIFICATIONS (Conforms to AEC-Q200)
Measurement condition
Electrical characteristics measured by S&A250B or equivalent.
Mechanical Endurance
Environmental Endurance
RELIABILITY SPECIFICATIONS
A: Frequency change: Within ±5ppm or in customer’s specification.
B: Frequency change: Within ±10ppm or in customer’s specification.
C: Equivalent series resistance (E.S.R) change: Within ±15% or 10Ω (larger value).
D: After conditioning, quartz crystal units shall be subjected to standard atmospheric conditions for 24 hour, and measured.
E: Minimum 95% of immersed terminal shall be covered with new uniform solder.
F: No damage on specimen